In this section:

Enterprise consists of multiple business locations and each business location is typically served by one of the following IP-PBX types.
In SBC Core configuration, the major differences while interworking with an IP-PBX in registration and static modes are as follows:

  • In Static mode, it is not required to route the registration messages for the IP-PBX.
  • In Registration mode, the route configuration to the IP-PBX is not required as the SBC identifies the endpoints dynamically through registration messages.

Asterisk (star) indicates the fields are mandatory.

Prerequisite

You can use the default Address Context or create a new Address Context. Prerequisites for the workflow SIP Enterprise Access (Carrier-hosted IP-PBX) are:

  • Address context
  • IP Interface group
  • IP Interface

Workflow

This section provides a high-level understanding of SIP Enterprise Access Provisioning.

Figure 1: SIP Enterprise Access - Carrier Hosted - Workflow

 

SIP Enterprise Access (Carrier-hosted IP-PBX) Provisioning Flow

The following figure shows the provisioning flow of the SIP Enterprise Access.

Step 1: Set up a Zone

Figure 2: SIP Enterprise Access - Carrier Hosted 1

Perform the following tasks to set up the Zone.

  1. Select SIP Enterprise Access > Zone.
  2. In the Address Context drop-down list, select the address context.
  3. Select the Zone from the drop-down list.  
  4. Click Next .
  5. To create a new zone, click Create New Zone next to Zone drop-down box and enter the following details:
    • Zone Name
    • DNS Group
    • Zone Id
  6. Click Save.

For more information on creating Zone, refer to System Provisioning - Zone.


Step 2: Add a SIP Trunk Group

Figure 3: SIP Enterprise Access - Carrier Hosted 2

 Perform the following procedure to add the SIP Trunk Group.

  1. Enter the SIP Trunk Group Name.
  2. Enter the details of the following:
    1. Policy
    2. Packet Outage
    3. Call Reservation
    4. CAC
    5. Services
    6. Media
    7. Call Routing
    8. Ingress IP Prefix
  3. Click Next .

Click Yes to add more SIP Trunk Groups and click No to proceed.

Step 3: Finish and Save

Click Finish and Save. The result of this action is displayed.

Click OK to exit.