Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.4.0.5

Description

This trap indicates that for a given emergency call the SBC is unable to route the call on any of the provided routes. This is a warning indicator of a failed emergency call.

Repetition

None

Event Codes

sonusActiveCallIngressPstnTrunk—For calls originating from PSTN (circuit) side, specifies the Trunk Group name to which the Ingress PSTN channel belongs.
sonusNodeResourceIsupCircuit—Base circuit identity code (CIC) for the circuit.
sonusActiveCallCallingNum—The E.164 number representing the calling party's telephone number.
sonusActiveCallCalledNum—The E.164 number representing the called party's telephone number.
sonusActiveCallOrigCalledNum—If an address translation is performed on the called party number, this entry contains the original, untranslated number.

Instance Fields

None

Action

Investigate why the calls are failing

Impact

Emergency calls will not route

Clearing

Manual

  • No labels