Type: CRITICAL

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.19.0.11

Description

This alarm indicates that the SBC has not successfully registered with the RAMP for an extended period of time. The SBC will soon operate in an unsanctioned manner from a licensing perspective.

Repetition

The alarm repeats once a day.

Event Codes

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription

Instance Fields

  • sonusLicenseManagerGracePeriodStart
  • sonusLicenseManagerGraceDaysLeft
  • sonusLicenseManagerGraceHoursLeft

Action

Check the logs on the License Manager and correct the issues listed.

Impact


Note

If the SBC remains disconnected from the managing RAMP instance for an extended period of time, the SBC will operate in an unsanctioned manner from a licensing perspective. Reconnect the SBC to the managing RAMP instance.

Contact Ribbon Global Product Support for more information regarding the need for the SBC to remain in constant contact with the managing RAMP instance.

Clearing

Automatic; sonusCpLicenseManagerRegistrationSucceeded