This object allows you to configure the signaling timers for the gateway.
To View and Edit Gw Sig Timers
On SBC main screen, go to Configuration > Profile Management > Category: Signaling Timers > Gw Sig Timers.
The Gw Sig Timers window is displayed.
Figure 1: Profile Management - Signaling Timers - Gw Sig Timers
The following fields are displayed:
Table 1: Gw Sig Timers parameters
Parameter | Description |
---|---|
Establish | Specifies the Gateway Signal Channel Establishment Timer (in seconds.) This value applies to all signal channels. The value ranges from 1 to 65535 and the default value is 10 seconds. |
Keepalive | Specifies the Gateway Signal Channel Keepalive Timer (in seconds.) This value applies to all signal channels. The value ranges from 1 to 65535 and the default value is 3 seconds. |
Retry | Specifies the amount of time (in minutes) the SBC will continue to attempt to recover a GW Signaling Link as long as there are stable calls up. The value ranges from 1 to 65535 and the default value is 60 seconds. |
Idle | Specifies the amount of time (in hours) a GW Signaling Link May be idle before it is taken down. If set to 0, the link will not be taken down. The value ranges from 0 to 65535 and the default value is 0. |
Cong Rel Delay | Specifies the amount of time (in seconds) that a call which is rejected due to congestion will be delayed before the release is issued. Prevents re-attempts from causing overload conditions. The value ranges from 0 to 5 and the default value is 0. |
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.