IMPORTANT

The SBC 5100, SBC 5110, SBC 5200, and SBC 5210 platforms are no longer supported beginning with the SBC Core 10.0.0R0 release. This release supports SBC 5400/7000/SWe/CNe platforms. Contact Ribbon Sales for upgrade information.

 

In an HA configuration, the two SBC Core platforms are connected to each other with the two HA ports using a pair of GigE cables. The connection provides both box-level and port-level redundancy. The HA pair consists of four management ports; two ports each per platform. When switchover occurs, the logical management address follows the currently active server. The packet ports, the MAC and IP addresses float between the HA pair (are replicated from active to standby on switchover).


A logical management address is the IP address associated with a Logical Management IP Interface previously created using EMA or CLI.

See the following pages to configure a Logical Management IP Interface:

Connect HA cables between the HA pair as shown:

Active   HA0<--------->Standby HA0

Active   HA1<--------->Standby HA1


Note

The SBC fails to pair with a machine that is not functionally equivalent in an upward compatibility configuration. During system installation and startup, make sure that the servers are designed to operate together and support full redundancy and high availability. Also, an HA pairing between the SBC 7000 is forbidden. 

HA Pair Setup between two SBC Platforms



  • No labels