This object specifies the packet outage detection parameters for this Gw Trunk Group.

To View and Edit Packet Outage

On SBC main screen, navigate to All > Address Context > Zone > Gw Trunk Group > Packet Outage.

The Packet Outage can be checked for each Address Context, Zone, and Gw Trunk Group or for all the Address Contexts, Zones, and Gw Trunk Groups created. Use the drop-down box to select the desired Address Context, Zone, and Gw Trunk Group.

The Packet Outage window is displayed.

Figure 1: All - Address Context - Zone - Gw Trunk Group - Packet Outage

The following fields are displayed:

Table 1: Packet Outage parameters

Parameter

Description

Minimum Duration

Specifies the minimum outage (in milliseconds) on a call for that call to be counted as part of the packet outage detection algorithm. The value ranges from 0 to 65535 and the default value is 6000.

Minimum Calls

Specifies the number of calls with outages required within the current interval to declare a packet outage event. The value ranges from 0 to 65535 and the default value is 1000.

Bandwidth Limit Reduction

Specifies the amount to reduce the bandwidth limit (as a percentage of the configured limit) when a packet outage is detected. The value ranges from 1 to 100 and the default value is 50.

Detection State

Use to enable automatic bandwidth reduction when a packet outage is detected.

  • disabled (default)
  • enabled

Detection Interval

Specifies the size of the packet outage detection interval in minutes. The value ranges from 5 to 1440 and the default value is 15.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

  • No labels