The BMC web application allows provisioning of NTP server.
Note
The SBC supports up to three NTP servers.
The following procedure describes how to configure the NTP server using BMC:
- Login to the SBC BMC GUI using the IP address configured in the previous section. The SBC BMC main screen displays.
Click Configuration > NTP and Date Time Settings. The NTP Settings screen is displayed.
- Select Automatically synchronize Date & Time with NTP Server option.
Enter the Primary NTP Server and Secondary NTP Server (not mandatory) IP address, and click Save.
- Click Save to save the edits made to NTP Settings.