Use the Operator Aggregate Policer window to set default values for aggregate policer options for cases when the values are not specified by the operator.

On the SBC main screen go to All > Address ContextOperator Aggregate Policer. The Operator Aggregate Policer window opens. Select the default Address Context.

Figure 1: Operator Aggregate Policer Window


Use the following table to enter values and then click Save.

ParameterDescription
Fill RateSpecify the default fill rate to use in aggregate policer rules if a value is not specified. The default is 20000 and the supported range is 1 to 32000, or unlimited.
Bucket SizeSpecify the default bucket size to use in aggregate policer rules if a value is not specified. The default is 50 and the supported range is 1 to 255, or unlimited.




  • No labels