Type: MAJOR
Object ID | 1.3.6.1.4.1.2879.2.10.1.1.1.0.37 |
Description | This alarm is raised when Authentication fails due to credentials mismatch between the SBC and AS. |
Repetition | None |
Event Codes |
|
Instance Fields | None |
Action | If this alarm occurs repeatedly, operator intervention is required to check if the password is correctly set at the SBC and AS. |
Impact | If the mismatch happens during a call, then the call is cleared. If this happens during registration, surrogate registration is deleted and the retry timer is restarted. |
Clearing | Automatic (sonusSbxSurrRegAuthenticationClearNotification), This clearing alarm is raised when surrogate registration is disabled. The corrective action should be to check username/password so that it is similar to what is configured at application server. |
Overview
Content Tools