Type: CRITICAL

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.19.0.11

Description

This alarm indicates that the SBC has not successfully registered with the EMS/RAMP for an extended period of time. The SBC will soon operate in an unsanctioned manner from a licensing perspective.

Repetition

The alarm repeats once a day.

Event Codes

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription

Instance Fields

  • sonusLicenseManagerGracePeriodStart
  • sonusLicenseManagerGraceDaysLeft
  • sonusLicenseManagerGraceHoursLeft

Action

Check the logs on the License Manager and correct the issues listed.

Impact

If the SBC remains disconnected from the managing EMS/RAMP instance for an extended period, it will result in the SBC operating in an unsanctioned manner from a licensing perspective. Reconnect the SBC to the managing EMS/RAMP instance. Contact Ribbon Global Product Support for more information regarding the need for the SBC to remain in constant contact with the managing EMS/RAMP instance.

Clearing

Automatic; sonusCpLicenseManagerRegistrationSucceeded