Use the Flags window to configure redirecting capability flags in a Signaling Profile.
To View and Edit Flags
On the SBC main screen, go to Configuration > Profile Management > Category: Signaling Profiles > Signaling Profile > Egress > Redirection Capability Flags > Flags or
All > Profiles > Signaling > Signaling Profile > Egress > Redirection Capability Flags > Flags
Select the Signaling Profile you want to configure from the drop-down list. The Flags window is displayed.
This window displays parameters only when the Redirection Capability Flags option is enabled. Refer to Egress - Redirection Capability Flags - Profile Management.
Figure 1: Redirection Capability Flags - Flags
Use the following table to configure the options and then click Save.
Table 1: Redirection Capability Flags - Flags Parameters
Parameter | Description |
---|---|
Check Carrier Code Combination | When enabled, SBC matches the carrier code in the call against configured carrier codes in the Carrier Code Combination Profile. The options are:
|
Check Ingress Trunk Grp Redirection Capability | When enabled, SBC checks for Ingress Trunk Group redirection capabilities. The options are:
|
Check Number Control Profile For Received Called Number | When enabled, SBC checks the Number Control Profile for a match on the received called number. The options are:
|
Check Received Redirection Params | When enabled, SBC checks for both the redirection capability parameter and the redirection information parameter. The options are:
|
Check Redirection Cap of Number Used for Routing In Number Control Profile | When enabled, SBC checks for redirection capabilities for the number used for routing. The options are:
|
Check SIP Indirect Dip And Username Translation Source Number | When enabled, SBC checks whether the received request is a SIP Indirect DIP and whether it contains the Translation Source Number. The options are:
|
Create Called Directory Number in Egress Signal On Redirection | When enabled, the original called party is sent by the SBC as the Called Directory Number. The options are:
|
Skip Redirection On RACIndication Set | When enabled, if the Representative Area Code indicator is set to On in the JTI parameter, the SBC does not perform redirection. The options are:
|