DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.14.0.23
DescriptionThis alarm indicates that a service license required for configuring a service cannot be retrieved from the license server. Due to the unavailability of the required license, licensed functionality is denied by the SBC. This alarm is raised for each instance of unavailable service license.
RepetitionOnce per license, and once every hour till the required service license not acquired.
Event Codes
  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusAlarmName
Instance FieldssonusAlarmName
ActionCheck whether the  required licenses are applied at the license server.
ImpactThe specified service license is unavailable at the license server, and the SBC denies the associated service.
ClearingAutomatic; sonusSbxServiceLicenseAvailable

  • No labels