DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.1.0.56

Description

This trap indicates that validation failed for the first STUN message for that call leg (local IP address type is IPv6).

Repetition

None

Event Codes

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusSipIceGcid
  • sonusSipIceRemoteIpV6Address
  • sonusSipIceLocalPort
  • sonusSipIceLocalIpV6Address
  • sonusSipIceLocalPort
  • sonusSipIceFailReason(string)

Instance Fields

  • sonusSipIceGcid
  • sonusSipIceRemoteIpV6Address
  • sonusSipIceLocalPort
  • sonusSipIceLocalIpV6Address
  • sonusSipIceLocalPort
  • sonusSipIceFailReason(string)

Action

Check with the operator at the remote end point regarding the sending of invalid messages.

Impact

The invalid STUN message is not processed, and failure to authenticate may indicate that spoofed packets are received.

Clearing

Manual