DO NOT SHARE THESE DOCS WITH CUSTOMERS!
This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.
Type: MAJOR
Object ID | 1.3.6.1.4.1.2879.2.8.1.2.1.18.0.1 |
Description | After bringing down the HA port on the active node, the standby role is set to active. On the new active node, some IPV6 pkt ports contain the error 'tentative dadfailed' . When 'tentative dadfailed' is detected on some ports, check the configurations/logs and take action accordingly. This alarm is triggered only when some IPV6 pkt ports contain the error 'tentative dadfailed'. |
Repetition | This alarm is triggered when some IPV6 pkt ports contain the error 'tentative dadfailed'. |
Event Codes |
|
Instance Fields | sonusDuplicateIpv6Address |
Action | Verify/correct specific configurations. Otherwise, reboot the node. |
Impact | Calls are rejected as duplicate address is detected. |
Clearing | Alarm clears automatically after node reboots. |