DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

Type: INFORMATIONAL

Object ID1.3.6.1.4.1.2879.2.10.1.1.12.0.5

Description

This alarm indicates that the service change handoff is received and is cleared  automatically by "sonusH248ScNotificationClear" notification after the association is established with the secondary MGC.

Repetition

None

Event Codes

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId

Instance Fields

  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusH248SigRemoteIpAddr
  • sonusH248SigLocalIpAddr
  • sonusH248SigScMethod
  • sonusH248SigMid

Action

None

Impact

Calls could fail if the VMG association is not established after handoff with the secondary MGC.

Clearing

Automatic; sonusH248ScNotificationClear.