DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.1.0.5

Description

This alarm indicates that all Network Timing Protocol Servers are Out of Sync.

Repetition

None

Event Codes

sonusCpSystemServerName

Instance Fields

None

Action

Investigate cause for this out-of-sync condition. A probable cause is that NTP protocol (communication between NTP servers and node) was interrupted.
To reference NTP Server CLI commands syntax, parameters and examples, see "NTP Services Management" section in SBC Core CLI Reference Guide.

Impact

Call processing will continue. Timestamps in log files and call accounting records will drift from the actual time on NTP server. If the drift becomes great enough, there may be slight discrepancies in billing records.

Clearing

Manual