Type: MAJOR
                                                                                                                                                                                                                                                                                                                  

Object ID1.3.6.1.4.1.2879.2.8.1.4.1.1.0.1

Description

This alarm indicates the specified chassis power supply failed.

Repetition

None

Event Codes

sonusConnexIpSystemAdminName
sonusConnexIpSystemServerName
sonusConnexIpSystemPowerSupplyId

Instance Fields

None

Action

Replace the power supply or source of power.

Refer to the respective hardware installation guide for power supply replacement procedures.

Impact

The server is running without power supply redundancy. If the second power supply fails during this time, the server will go down.

Clearing

Automatic, sonusConnexIpSystemCEPowerSupplyNormalNotification