DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

In this section:

The IP Policing Alarm Profiles specify parameters to determine when alarms associated with IP policing are generated and cleared.

To View IP Policing Alarm Profiles

On the SBC main screen, go to Configuration > Profile Management > Category: System Profiles > IP Policing Alarm Profile.

The IP Policing Alarm Profile window is displayed. A  portion of the window is shown below.

IP Policing Alarm Profile window

To Create an IP Policing Alarm Profile

To create a new IP Policing Alarm Profile, click New IP Policing Alarm Profile on the IP Policing Alarm Profile List window.

The Create New IP Policing Alarm Profile window is displayed.

Create New IP Policing Alarm Profile Window

The following fields are displayed:

IP Policing Alarm Profile Parameters

Parameter

Description

Name

Specify the name of the IP Policing Alarm profile.

Index

A unique identifier.

State

Administrative state of IP Policing alarm profile.

Bad Ethernet IP Header Set Threshold

Specifies the threshold for the bad Ethernet IP header policer discard rate which may set an alarm. The default value is 100.

Bad Ethernet IP Header Clear Threshold

Specifies the threshold for the bad Ethernet IP header policer discard rate which may clear an alarm. The default value is 20.

Bad Ethernet IP Header Set Duration

Specifies the duration (in seconds) that the bad Ethernet IP header policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3.

Bad Ethernet  IP Header Clear Duration

Specifies the duration (in seconds) that the bad Ethernet IP header policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3.

ARP Set Threshold

Specifies the duration (in seconds) that the bad Ethernet IP header policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 100.

ARP Clear Threshold

Specifies the threshold for the ARP policer discard rate which may clear an alarm. The default value is 20.

ARP Set Duration

Specifies the duration (in seconds) that the ARP policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3.

ARP Clear Duration

Specifies the duration (in seconds) that the ARP policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3.

U Flow Set Threshold

Specifies the threshold for the micro flow policer discard rate which may set an alarm. The default value is 100.

U Flow Clear Threshold

Specifies the threshold for the micro flow policer discard rate which may clear an alarm. The default value is 20.

U Flow Set  Duration

Specifies the duration (in seconds) that the micro flow policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3.

U Flow Clear  Duration

Specifies the duration (in seconds) that the micro flow policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3.

ACL Set Threshold

Specifies the threshold for the access control list (ACL) policer discard rate which may set an alarm. The default value is 100.

ACL Clear Threshold

Specifies the duration (in seconds) that the access control list policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3.

ACL Set Duration

Specifies the duration (in seconds) that the access control list policer discard rate must be at or above its set threshold before an alarm is set. A value of 0 sets the alarm immediately.

ACL Clear Duration

Specifies the duration (in seconds) that the access control list policer discard rate must be at or below its clear threshold before an alarm is cleared. A value of 0 clears the alarm immediately.

Aggregarte Set Threshold

Specifies the threshold for the aggregate policer discard rate which may set an alarm. The default value is 100.

Aggregarte Clear Threshold

Specifies the threshold for the aggregate policer discard rate which may clear an alarm. The default value is 20.

Aggregate Set Duration

Specifies the duration (in seconds) that the aggregate policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3.

Aggregate Clear Duration

Specifies the duration (in seconds) that the aggregate policer discard rate must be at or below its clear threshold before an alarm is cleared. A value of 0 clears the alarm immediately.

IP Sec Decrypt  Set Threshold

Specifies the threshold for the IPSEC decrypt policer discard rate which may set an alarm. The default value is 100.

IP Sec Decrypt Clear Threshold

Specifies the threshold for the IPSEC decrypt policer discard rate which may clear an alarm. The default value is 20.

IP Sec Decrypt  Set Duration

Specifies the duration (in seconds) that the IPSec decrypt policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3.

IP Sec Decrypt Clear Duration

Specifies the duration (in seconds) that the IPSec decrypt policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3.

Media Set Threshold

Specifies the threshold for the media policer discard rate which may set an alarm. The default value is 100.

Media Clear Threshold

Specifies the threshold for the media policer discard rate which may clear an alarm. The default value is 20.

Media Set  Duration

Specifies the duration (in seconds) that the media policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3.

Media Clear Duration

Specifies the duration (in seconds) that the media policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3.

Rogue Media Set Threshold

Specifies the threshold for the rogue media policer discard rate which may set an alarm. The default value is 100.

Rogue Media Clear Threshold

Specifies the threshold for the rogue media policer discard rate which may clear an alarm. The default value is 20.

Rogue Media Set Duration

Specifies the duration (in seconds) that the rogue media policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3.

Rogue Media Clear Duration

Specifies the duration (in seconds) that the rogue media policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3.

Discard Rule Set Threshold

Specifies the threshold for the discard rule discard rate which may set an alarm. The default value is 20.

Discard Rule Clear Threshold

Specifies the threshold for the discard rule discard rate which may clear an alarm. The default value is 10.

Discard Rule Set Duration

Specifies the duration (in seconds) that the discard rule discard rate must be at or above its set threshold before an alarm is set. A value of 0 sets the alarm immediately.

Discard Rule Clear Duration

Specifies the duration (in seconds) that the discard rule discard rate must be at or below its clear threshold before an alarm is cleared. A value of 0 clears the alarm immediately.

Srtp Decrypt Set ThresholdThe threshold for the SRTP decrypt policer discard rate which may set an alarm. The default value is 20
Srtp Decrypt Clear ThresholdThe threshold for the SRTP decrypt policer discard rate which may clear an alarm. The default value is 10.
Srtp Decrypt Set Duration

The duration (in seconds) that the SRTP decrypt policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3.

Srtp Decrypt Clear Duration

The duration (in seconds) that the SRTP decrypt policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3.

Make changes to the parameter values as needed and click Save to create the profile.

To Edit an IP Policing Alarm Profile

  1. To edit an IP Policing Alarm Profile, click the radio button next to the specific IP Policing Alarm Profile name. The Edit Selected IP Policing Alarm Profile window is displayed.
  2. Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

To Copy an IP Policing Alarm Profile

  1. To copy an IP Policing Alarm Profile, click the radio button next to the specific IP Policing Alarm Profile to highlight the row.
  2. Click Copy IP Policing Alarm Profile. The Copy Selected IP Policing Alarm Profile window is displayed.
  3. Make any changes to the required fields and click Save to save the changes. The new IP Policing Alarm Profile based on the copied profile is added at the bottom of the list.

To Delete an IP Policing Alarm Profile

  1. To delete any of the created IP Policing Alarm Profiles, click the radio button next to the specific IP Policing Alarm Profile which you want to delete.
  2. Click the X at the right end of the highlighted row. 
  3. Click Yes to confirm the deletion when prompted.

 

  • No labels