DO NOT SHARE THESE DOCS WITH CUSTOMERS!
This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.
Network-wide licensing using a site license server (SLS) has been discontinued and is no longer available on SBC 8.0 or later releases.
Use the Required License window to to restrict specific node instances to a subset of a domain's licensed capacity, if needed. Entries in the Required License List are optional and only apply when using network-wide domain licensing (NWDL), that is, when operating in domain license mode. When present, the entries specify limits on the license capacity allowed for the node. By default, no limits are configured; the absence of entries in the Required License List indicates that the node is entitled to use the entire capacity assigned to the SBC cluster by its NWDL license.
If you choose to specify any restrictions then you must configure appropriate limits for all counted features and also include entries for any on/off features you want to enable. If the Required License List contains a limit for any feature, any other features that are not included in the table are treated as having a license count of 0 and are effectively disabled. If you are using the full-capacity licensing option enabled by the SBC-CAPACITY-D license key, then any Max Count values you specify in Required License entries are ignored.
To view the list of configured required license entries, on the SBC main screen navigate to Administration > System Administration > License Management > Network License Settings > Required License or
All > System > Required License
The Required License window opens.
The Required License window consists of two tables:
License Info List - A table that displays detailed information on the domain licenses on the SBC.
To create a new required license entry:
Click New Required License. The Create New Required License window opens.
Select the license key name for the licensed feature for which you want to specify a limit from the Feature Name list. Refer to NWDL Feature License Keys.
If you specify a limit for any feature, you must include an entry for every other feature you want to enable, including features that are not counted (on/off features) or counted features that you do not want to limit (unlimited).
To edit the required license entry for a feature:
Click the radio button adjacent to the feature name in the Required License List table. The Edit Selected Required License window opens.
To copy an existing required license entry to apply it to another feature:
Click the radio button adjacent to the feature name in the Required License List table.
Click Copy Required License. The Copy Selected Required License window opens.
To delete the required license entry for a feature:
CClick the radio button adjacent to the feature name in the Required License List table.
Click the X (Delete icon) at the right end of the row.