DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

MultiExcerpt named Stop LMSD Tones On Update was not found -- Please check the page name and MultiExcerpt name used in the MultiExcerpt-Include macro

For additional details, refer to:

 

Command Syntax

% set addressContext <addressContext name> zone <name> sipTrunkGroup <sipTrunkGroup name> signaling stopLmsdToneOnUpdate <disabled | enabled>

Command Parameter

Stop LMSD Tone On Update Parameter

ParameterDescription

stopLmsdToneOnUpdate

For calls originating from the MSC server, enable this flag to send a split response on the leg which receives the a ringing tone from the MSC in order to force the MSC to stop the ringback tone: 1) Send a 180 ringing without SDP with Alert-Info <http:/null> to stop the LMSD tone, and 2) Send an update with the SDP offer.

  • disabled (default)
  • enabled

NOTE: The 180 ringing is sent only if the SBC has relayed the Alert-Info with the non-null URI.

  • No labels