DO NOT SHARE THESE DOCS WITH CUSTOMERS!
This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.
Use this Post-Dial Delay (PDD) object to configure post-dial delay performance requirement which consists of a timeout value and response code.
The Ingress PDD timer is activated when the configured value on the ingress trunk group is greater than zero and the incoming SIP call reaches an address complete state.
The Egress PDD timer is activated when the configured value on the egress trunk group is greater than zero and upon receipt of the 100 Trying message from the egress peer. The Egress PDD timer is canceled upon receipt of a 18x/200/3xx/4xx/5xx message from the egress peer.
Refer to Post Dial Delay Timer for additional feature details.
% set addressContext <name> zone <name> sipTrunkGroup <name> signaling postDialDelay responseCode (400-699) timeOut (0-20000 milliseconds)