DO NOT SHARE THESE DOCS WITH CUSTOMERS!
This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.
In this section:
The SBC 51xx and SBC 52xx platforms are not supported from release 11.0.0 onwards. This release supports the SBC 5400, SBC 7000 and SBC SWe platforms.
The front Bezel is a Customer Replaceable Unit (CRU). The purpose of the Bezel is to encase the replaceable air filter and to identify the LED status indicators (Power, Status, Active, Alarm, Locator) on the front panel of the chassis, as shown in the next two figures. The two Bezel product codes are listed below:
Perform the following procedure to replace the Bezel:
Locate the tab on the left side of the Bezel and pull back on Bezel until the left ball stud mounts disengage from the chassis.
Grasp the right-side of the Bezel and pull the Bezel away from the chassis until the right ball stud mounts disengage from the chassis.
All SBC 5000 series CRUs are shipped in electrostatic discharge bags and should be handled using appropriate ESD precautions.
The storage environment for the CRUs are: