DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

Use this object to provision the HPC call limits for the SIP CAC profile for the trunk group.

Note

The use of the GETS SOFTWARE is restricted in the U.S. and U.S. TERRITORIES to NS/EP users authorized by the Office of the Manager, National Communications System (OMNCS).

  1. Log on to the EMA as admin and navigate to All > Profiles > SIP CAC Profile > Hpc Call Limits.
  2. The Hpc Call Limits window displays. Select a SIP CAC Profile from the drop-down list.

    Select SIP CAC Profile

  3. The Edit Hpc Call Limts window displays.

    Edit Hpc Call Limits

  4. Edit the fields in th Edit Hpc Call Limts window.

    Edit Hpc Call Limits

    fieldLength/RangeDefaultDescriptionM/O
    Max Calls N/Aunlimited

    Use this field to configure the maximum number of simultaneous HPC calls.

    • blockAll
    • unlimited (default)
    • <1-1000>
    O
    Max Ingress RateN/Aunlimited

    Use this field to configure the maximum rate of ingress HPC calls per interval minute.

    • unlimited (default)
    • <1-2000>
    O
    Ingress Rate Interval1-305Use this field to configure the interval (in minutes) for the ingress rate of HPC calls.O
    Bucket Size1-400010Use this field to limit the rate of received HPC calls.O

  5. Click Save.