DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

 

This profile specifies the CAC parameters related to H323 Trunk Group.

To View and Edit H323 Trunk Group - CAC

On SBC main screen, go to Configuration > System Provisioning > Category: Trunk Provisioning > Trunk Group > H323Trunk Group > CAC. The CAC window is displayed.

The H323 Trunk Group - CAC can be checked for each Address Context, for each Zone, for each H323Trunk Group created or for all the Address Contexts, Zones and H323Trunk Groups created. Use the drop-down list to select the desired Address Context, Zone and H323Trunk Group.

H323Trunk Group - CAC Main Fields

The Edit CAC window is displayed.

H323Trunk Group - CAC Edit Window

The following fields are displayed:

H323Trunk Group - CAC Parameters


Parameter


Description

Call LimitThe total number of concurrent calls (either ingress or egress) allowed. Enter unlimited or value in range of 0-2147483647.
Bandwidth LimitTotal media bandwidth limit (in K bits/sec). Enter unlimited or value in range of 0-  2147483647.
Call Limit ThresholdSpecifies the call utilization notification threshold limit. The value range from 0 to 100.
Bandwidth Limit ThresholdSpecifies the bandwidth utilization notification threshold limit. The value range from 0 to 1000.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

 