DO NOT SHARE THESE DOCS WITH CUSTOMERS!
This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.
For every Feature Control Profile created, you have the option to choose whether to use the Ip Protocols or not.
The Ip Protocol flag, can be enabled or disabled for each Feature Control Profile created.
On SBC main screen, go to Configuration > Profile Management > Category: Feature Control Profile > Feature Control Profile > Ip Protocol Flags.
Select the desired Feature Control Profile from the drop-down list to view its respective Ip Protocol Flags parameters.
The Ip Protocol Flags window is displayed.
The following fields are displayed:
Parameter | Description |
---|---|
| Specifies whether to use the Ip Protocol or not for the created Feature Control Profiles. The options are:
|
Default Called User | This parameter is visible only when If enabled, the application User Name is used the Default Called User value. The options are:
|
Honor Phone Context Parameter | When this flag is enabled, PSX globalizes the incoming called number using the phone-context value received in Called-URI. Once the number is globalized using phone-context, the PSX acts as if it received a global number in policy request and use the modified number for further call processing. The options are:
This parameter is visible only when |
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.