Type: MINOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.20.0.6

Description

The alarm indicates SBC connection to VNFM cannot be established. Triggered if the SBC fails to successfully register with VNFM upon startup or subsequently if the heartbeat between SBC and VNFM is missed.

Repetition

Each time the heartbeat is lost between the SBC and VNFM.

Event Codes

sonusAlarmNodeID
sonusAlarmLevel
sonusAlarmSequenceId           
sonusAlarmTime
sonusAlarmDescription
sonusVnfmUrlName

Instance Fields

sonusVnfmUrlName

Action

Make sure VNFM is reachable.

Impact

Availability of VNFM connection is lost.

Clearing

Automatic; sonusVnfmConnectionSucceeded


 

 

The VNFM interoperates with the SBC SWe only.