Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.21.0.8

Description

Port Redundancy Group detected link failure toggling.

Repetition

Occurs when Port Redundancy Group detects link failure toggling.

Event Codes

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusNrsCeName

  • sonusLvmPortRedundancyGroupName

Instance Fields

  • sonusNrsCeName

  • sonusLvmPortRedundancyGroupName

Action

Examine the health of the failed links and repair them.

Impact

Automatic port switchovers to re-establish failed links stop.

Clearing

automatic; sonusSbxLvmPrgLinkFailureToggleClearedNotification

Note: In certain instances, you must clear this alarm manually; for example, after node switchover (if the links do not recover before toggleRecoverTimer expiry).