IMPORTANT

The SBC 5110 and SBC 5210 hardware platforms are no longer supported beginning with the 10.0.0R0 release. This release supports SBC 5400/7000/SWe platforms. Contact Ribbon Sales for upgrade information.

Identify and download the correct firmware file for your platform type. The upgrade fails if the selected firmware upgrade file does not match the platform type. The following table identifies the correct firmware files for an upgrade:

Platform TypeFirmware file
SBC 5400

Upgrade from any version to latest version:

  • firmware-5400-V03.xx.00-R000.img
  • firmware-5400-V03.xx.00-R000.img.md5
SBC 7000 (Refer to Upgrading the BMC and BIOS Firmware for the procedure.)

Upgrade from any version to latest version:

  • firmware-7x00-V03.xx.00-R000.img
  • firmware-7x00-V03.xx.00-R000.img.md5

Upgrade Paths

There are two BMC firmware upgrade procedures based on the version from which you are upgrading. Each method requires a different file type as listed in the previous table. The SBC 5400 supports only the upgrade method using the ".img" file.

  • BMC upgrade from 2.x to 3.x: Use the ".rom" file. 
    For example: To upgrade from BMC 02.16.00 to 03.17.00, use "bmc5X00_v3.17.0-R0.rom" file.

    Note

    The firmware upgrade to 3.x can only be done from version 02.16.00 or later. If the existing BMC version is older than 02.16.00, upgrade it to 02.16.00 using the ".rom" file first and then perform an upgrade to 3.x version using a ".rom" file.

  • BMC upgrade from 3.x to 3.y OR 1.x to 3.y: Use the ".img" file. 

For example: To upgrade from BMC 03.00.00 to 03.17.00, use "firmware-5XX0-V03.17.00-R000.img" file.

Note

Download the required BMC firmware version prior to continuing. Refer to Downloading Software from the Ribbon Support Portal for details.

Note

Windows and/or dialog boxes depicted in this section are intended as examples only and may not reflect the actual software/firmware versions applicable to you. Refer to any associated hardware/software requirements as well as the relevant release note for software/firmware version details. 

Upgrading BMC Firmware from Version 3.x or 1.x

The following procedure describes how to upgrade the BMC firmware from a 3.x version to a 3.y version (for example, from version 03.10.00 to version 03.17.00) or from 1.x to a 3.x version using the ".img" file.

  1. Log on to the SBC BMC GUI.

    BMC Login Screen

    The BMC main screen is displayed.

    SBC BMC Main Screen

  2. Click Firmware Update.

    BMC Firmware Update option


    The Firmware Update screen is displayed.

    BMC Firware Update screen

  3. Click Browse, and from the Open dialog browse to and select the firmware image (for example; firmware-5XX0-V03.17.00-R000.img). Refer to the table at the start of this page to make sure you have chosen the correct type of file for an upgrade. To determine the exact firmware version, refer to the release notes in SBC Release Information.
     

  4. Click Upload.

    Note

    The firmware image is approximately 24MB for the SBC 5400 and takes few minutes to upload based on the network.

    Note

    The BMC fails to upgrade if:

    • the selected version is same as the existing version.
    • the selected version is older than the existing version.
    • the selected firmware image is incorrect for the platform type. 

     The selected file is verified and the uploading process starts.


  5. Once the file verification is complete, when prompted, click Confirm to proceed with the upgrade.

    Caution

    This is a service-affecting procedure and will power off the host side of the SBC.

    After you confirm, the BMC initiates an orderly shutdown of the host. If the process to shutdown the host fails, the upgrade fails. Take one of the following actions based on the current BMC version:

    • If the BMC version is less than 3.18-R000, reboot the BMC by issuing the "reboot" command from the BMC command line. After the BMC boots up, shut down the host manually before continuing with the upgrade.
    • If the BMC version is 3.18-R000 or greater, a reboot is not needed. Power off the host manually before continuing with the upgrade from step 2.

    Once the upload starts, the actions performed are displayed in the same window along with the estimated time left to complete the process.

    Warning

    Once the upgrade process starts, do not close the screen.

    • If the window is closed or connectivity is lost before the upgrade starts, log back into BMC GUI and restart the upgrade process from step 1.
    • If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact Technical Support for assistance.


    Once the update process is complete, a completion message displays.

    Firmware Update Complete message

  6. Click OK to complete the process.The BMC automatically restarts at this point.

  7. Close the existing browser window.

  8. Clear the browser cache and log on to the BMC GUI again. The updated BMC version is displayed on the BMC main screen.

  9. Log onto the BMC GUI.

     The SBC BMC prompts you to change the password after a successful upgrade only if it is a default password.

    Note

    This change is applicable only when the BMC is upgraded to version 03.16.00 and later versions


    Change Default Password Window

  10. Click OK to proceed. The User Management window is displayed.

    Note

    You have an option to cancel the action. If canceled, the password remains the same as the default password and you are allowed to continue to work on BMC. However, the warning message is displayed again on your next login to BMC. This reminder continues until the password is changed. To know more about how to successfully change the SBC BMC password, refer to Changing the BMC Password

  11. Verify the upgraded version in the BMC main screen.

Note
For HA configuration, refer to Upgrade Flows for guidance.