This object defines when to generate/clear an alarm for Ethernet CRC failures. A Major alarm (sonusSystemSecurityEthernetErrorNotification)
is raised when the current Ethernet CRC rate is above the setThreshold
value, and is cleared (sonusSystemSecurityEthernetClearNotification)
once the error rate goes below the clearThreshold
value. Refer to SBC Core Alarms Guide to know more about these two alarms (you can search for these alarms).
To View and Edit Ethernet Crc Err Alarm
On SBC main screen, go to All > OAM > Alarm > Ethernet Crc Err Alarm. The Ethernet Crc Err Alarm window is displayed.
The following fields are displayed:
Parameter | Description |
---|---|
Set Threshold | The threshold value to set this alarm. The value ranges from 0 to 2147483647 and the default value is 0. A value of "0" disables the alarm. |
Clear Threshold | The threshold value to clear this alarm. The value ranges from 0 to 65535 and the default value is 100. |
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.