In this Section:
Use this object to configure HPC call queuing for trunk groups.
Edit Queue
- Log on to the EMA as admin and navigate to All > Profiles > Services > Hpc Call Profile > Queue.
- The Queue window displays. Select a Hpc Call Profile from the drop-down list.
- The Edit Queue panel displays.Note
By default, the SBC sends a response code 600 when the call queue is full. To configure the SBC to send the response code 503 when the call queue is full, execute similar commands as described below:
% set profiles signaling sipCauseCodeMapping cpcToSipCauseMapProfile TEST baseProfile defaultCpcSip causeMap 161 sipCause 503
% set addressContext default zone ZONE1 sipTrunkGroup INGRESS_TG signaling causeCodeMapping cpcSipCauseMappingProfile TEST
% commit
- Edit the values and click Save.
For more information and configuration examples, refer to HPC Call Profile - CLI.