In this section:
The Cluster Admin commands control communications among SBC nodes in a cluster configuration. You must configure the clusterAdmin clusterComm
options on M-SBC clusters in a distributed SBC SWe deployment. This configuration is visible only for M-SBC clusters and must be completed prior to configuring a load balancing service to distribute media request among the media nodes.
You must restart the SBC after changing the IP address for intra-cluster communication.
Command Syntax
The following syntax shows the first-level parameters under clusterAdmin
. The subsequent options differ depending on the option you specify for type
.
% set system clusterAdmin clusterComm type <ip | mgmt>
clusterComm Syntax (M-SBC Deployments Only)
Intra-cluster communications can be configured to occur on either the management interface (default) or a packet interface. The parameters differ based on the type
specification as shown below.
% set system clusterAdmin clusterComm type ip addressContext <addressContext name> ipInterfaceGroup <IPIG name> pktIpVar <metaVariable>
% set system clusterAdmin clusterComm type mgmt mgmtInterfaceGroup mgmtGroup mgmtIpVar <metaVariable>
Command Parameters
The following table describes the parameters under clusterAdmin clusterComm
you can use to configure intra-cluster communication for an M-SBC deployment.
Configuration Examples
To configure packet interface using IPv6 address for VNFC communication in an M-SBC cluster: To configure packet interface using IPv4 address for VNFC communication in an M-SBC cluster: To configure management interface using IPv6 address for VNFC communication in an M-SBC cluster: To configure management interface using IPv4 address for VNFC communication in an M-SBC cluster:% set system clusterAdmin clusterComm type ip addressContext default ipInterfaceGroup MLIG2 pktIpVar IF3.IPV6
commit
% set system clusterAdmin clusterComm type ip addressContext default ipInterfaceGroup MLIG2 pktIpVar IF3.IPV4
commit
% set system clusterAdmin clusterComm type mgmt mgmtInterfaceGroup mgmtGroup mgmtIpVar IFO.IPV6
commit
% set system clusterAdmin clusterComm type mgmt mgmtInterfaceGroup mgmtGroup mgmtIpVar IFO.IPV4
commit
Use the show table system clusterAdmin clusterComm
command to view configuration details. Refer to Show Table System for details.