Resources | node | system | powerSupplyStatus

powerSupplyStatus

Power consumption/state of the server.

Exists on Condition (/system/isOAM ='true') and (/NODE_LIST:node[NODE_LIST:nodeName=current()/../NODE_LIST:nodeName]/system/serverAdmin/hwType!='ConnexIP5000')

Operational Data

ParameterDescription
serverName Identifies the server.
powerSupplyId The name of the power supply (/SYS/VPS)
present Indicates if the module is present or not.
productName Identifies the name (as given by manufacturer) of power supply module.
serialNum Identifies the serial number of the power supply module. This is the serial number assigned to the server module at manufacture.
partNum Identifies the part number of the module. This is the part number assigned to the module at manufacture.
powerFault Indicates if there is power fault.
voltageFault Indicates if there is voltage fault.
RESTCONF API: GET Example

curl -kisu 'admin:secret' -X GET https://{SBX-SERVER}/restconf/data/sonusNodeList:node={nodeName}/sonusNodeListSystem:system/powerSupplyStatus={serverName},{powerSupplyId}