| Parameter | Presence | Type | Default | Description |
---|
| generationMode | O | enumeration | origination |
This configures the accounting generation mode for the node
|
| intermediateAcctState | O | enumeration | disabled |
This configures whether Intermediate Accounting is Enabled or
Disabled for the Node
|
| intermediateAcctInterval | O | int32 | 60 |
This configures the Intermediate Accounting Interval in seconds
Note: this object is only applicable when sonusAcctIntAcctMode
is set to interval(1).
|
| secondStageInheritFirstStage | O | boolean | false |
This indicates whether or not second stage accounting records for two
stage calls inherit fields from the first stage call.
|
| populateNonPortedLnpNumbers | O | boolean | true |
This indicates whether or not to populate the Called
Number Before Translation field in the accounting
record for a number for which an LNP lookup was
performed and the lookup indicated that the number
has not been ported.
|
| intermediateAcctMode | O | enumeration | interval |
This configures the intermediate record generation mode for
the node.
In INTERVAL(1) mode, intermediate records are generated
a periodic intervals following call establishment. This
interval is defined by sonusAcctIntAcctInterval.
In TELCORDIA(2) mode, intermediate records are generated once
per day for calls whose duration exceeds 24 hours. The
scheduled generated time is defined by
sonusAcctTelcoridaGenTime.
|
| intermediateLongDurGenTime | O | string | 00:00:00.0 |
Octet string that identifies the GMT time to generate Telcordia
Long Duration accounting records. At the scheduled time an
intermediate accounting record will be generated for all calls
whose duration exceeds 24 hours. Duration is measured from
Service Established time to the current time.
octet contents range
----- -------- -----
1 hour 0..23
2 minute 0..59
3 seconds 0..60
4 deci-seconds 0..9
For example, 23:59:59.9 GMT is represented as 0x173B3B09.
Note: this object is only applicable when sonusAcctIntAcctMode
is set to telcordia(2).
|
| startAcctState | O | enumeration | enabled |
This configures whether Start Accounting is Enabled or
Disabled for the Node. If START records are disabled, then
INTERMEDIATE records will also not be generated.
|
| eventAcctState | O | enumeration | disabled |
EVENT records will be generated if enabled.
|
| eventAcctPsxInfoState | O | enumeration | disabled |
EVENT records relating to PSX will be generated if enabled.
|
| intermediateTrapState | O | enumeration | disabled |
This configures whether a trap will be generated
whenever an INTERMEDIATE record is generated.
|
| populateRemoteGsxInfoState | O | enumeration | disabled |
This configures whether a destination NBS5200 propagates
its billing data to originating GSX/NBS for GW-GW calls.
If population state is enabled, then the destination NBS5200
will propagate billing information to originating GSX/NBS.
|
| earlyAttemptState | O | enumeration | disabled |
This configures whether early ATTEMPT accounting is enabled
or disabled. An early ATTEMPT record is associated
with early call disconnect before the Policy Request was sent.
|
| intermediateLongDurThreshold | O | uint32 | 24 |
This configures the Accounting Intermediate Records Duration
in hours.
When intermediate record generation mode (sonusAcctIntAcctMode)
is set to Telcordia,and the long duration time generation time
(sonusAcctIntLongDurGenTime) is reached, then an INTERMEDIATE
record will be generated for each call whose duration exceeds
this threshold.
Note: this object is only applicable when sonusAcctIntAcctMode
is set to telcordia(2). The units for this configuration
is in Hours
|
| sendEgressCdrInfoOnReceipt | O | boolean | false |
This indicates whether or not to send the egress
CDR info immediately after receiving and processing it.
|
| populateIpTgFarEndSwitchType | O | enumeration | disabled |
This configures whether or not we use Ingress Far End
Switch Type passed down from PSX IP TG for SIP ingress
calls or not.
|
| maxRecordSequenceNum | O | enumeration | uint16 |
This field configures the maximum record sequence number for logging
the CDR records. if the option uint32 is selected, the maximum
record sequence number is referred to 4294967295. Otherwise, the default
maximum sequence number 65535 is used.
Note: The run-time record sequence number will roll-over if its value
exceeded the configurable maximum record sequence number or the
default maximum record sequence number.
|
| generateSipRecordingCdr | O | enumeration | disabled |
This configures whether or not we generate CDR for Recording Calls.
|
| preventDuplicateEmptyStopRecOnInactivityDetection | O | enumeration | disabled |
This configures whether SBC should generate empty STOP record on inactivity detection.
|
| patchVer | O | uint32 | 0 | This command will roll the accounting file and print version specific fields |
| eventAcctMethods | O | | |
Log event records for the methods specified in the configuration.
|