In this section:

This section provides instructions to perform an upgrade on the EdgeMarc firmware using EdgeView. To perform these actions on EdgeView, follow the steps below.

Step 1: Set up a Firmware Repository

To set up an upgrade firmware repository: 

Set up an FTP server 

  1. Download, install, and run any Linux based FTP server software. 
  2. Create a folder for the FTP server in the format c:\ftp\root\e_XXXX\ ; where XXXX is the EdgeMarc device that needs to be upgraded. For example, EM2900POE would be: c:\ftp\root\e_2900\ .
  3. Create a login account on the FTP server with a username and a password.

Locate the EdgeMarc VOS files on FTP server

To locate the EdgeMarc VOS files on the FTP server, follow the steps given below:

  1. From the built FTP server,  locate the EdgeMarc VOS files into the EdgeView device.
  2. Select the base path from the created folder path on the FTP server.
  3. Log in to the EdgeView device to point the FTP server to the repository
Note

Base path is the absolute path to which the EdgeMarc VOS files are located. By default, the base path is in root.

Add Firmware Repository in EdgeView

To add a firmware repository on the EdgeView device, follow the steps given below:

  1. Choose System > Firmware Repositories. The EdgeView Firmware Repositories page appears.

  2. Click ADD REPOSITORY on the top-right corner. The Add Repository page appears.

  3. On the Add Repository page, enter the repository details of the selected device from its FTP server and enable the Map to Unassigned collection check-box.

  4. Click Add Repository. The repository overview page appears.

  5. On the overview page under the ACTIONS menu:
    1. Select Get Latest Versions to add the latest EdgeView versions on the device.
    2. Select Map Versions. The Map Versions dialog box appears, where you can select the latest GA build version for upgrading from EdgeView to EdgeMarc.

    3. Select Upload Firmware Versions to upload the required firmware versions.

Step 2: Create a Collection

To add a collection for the upgrade firmware, follow the steps given below:

  1. Choose Devices > Collections. The Collections page appears.

  2. Click ADD COLLECTION on the top right corner. The Add Collection page appears.

  3. On the Add Collection page, enter a name for the collection and select the created upgrade firmware repository from the Select Firmware Repository drop-down list. 
  4. Click ADD COLLECTION. A new collection is created.

For more details on EdgeView Collections, refer to Managing Collections.

Step 3: Add a Device to the Collection 

To add the required EdgeView device to the created collection, follow the steps given below:

  1. Choose Devices > List. The List page appears.

  2. On the list page, select the device you want to add to the collection from the list of EdgeMarc devices.
  3. Under the Bulk Actions menu, select Move to Collection.


    The Move to Collection page appears.

  4. On the Move to Collection page under Choose collection, select the created collection.

    Tip

    Enable the Send notification once Move is completed check-box if you want to receive notifications.

  5. Click Move 1 Device. You are prompted to confirm this action.

  6. Click MOVE NOW to confirm the action. The Action Log page appears.


    Here you can see that the device moved to the collection appears in the table.

For more details on EdgeView Collections, refer to Managing Collections.

Step 4: Upgrade the Firmware

To perform the firmware upgrade, follow the steps given below:

  1. On the Action Log page, select device that you added to the collection.


    The Device Overview page of that device appears.

  2. On the Device Overview page under the ACTIONS menu, select Upgrade Firmware.

    The Upgrade Firmware page appears.

  3. Under the Included Devices table, select the firmware version to which you want to upgrade the device (see Upgrade EdgeView).

    Tip

    Enable the Send notification once Upgrade is completed check-box if you want to receive notifications.

  4. Schedule when to upgrade your firmware by selecting Perform Now or Perform Later. If you decide to perform the upgrade later, enter the following details:
    • Schedule Name – Enter a schedule name of your choice.
    • Date and Time – Enter the date and time when the upgrade is to be performed.
    • Time Zone – Choose whether the time is to be calculated based on Local Time Zone or UTC.

  5. Click UPGRADE 1 DEVICE (refer to Upgrade EdgeView). You are prompted to confirm the upgrade.

  6. Select UPGRADE NOW to upgrade the selected device (see Confirm Upgrade).

    Note

    If you scheduled this action to be performed at a later point in time, you can edit this action at any point before the scheduled time. To edit, go to Jobs > Scheduled Jobs and click the Edit icon corresponding to this action. For more details on scheduling and editing a job, refer to Scheduling Jobs in EdgeView.

    Note

    Devices that are not moved to the created collection cannot be upgraded using the above steps. If you try to upgrade such a device, the following message is displayed:

    "This action will not be performed on these devices due to insufficient permission or other conditions. See details in table."