Number7348
SeverityCritical
SNMP NameptSUAASPSuaAssocMinStreamsFail
DescriptionAn SUA ASP Association has been established with less than the minimum of two steam requirement.
ApplicationSignaling Gateway
ActionSee the following Recommended Action

Recommended Action

If this alarm is raised, do the following.

  1. Log in to the Web UI.

  2. Locate the Alarm.
    1. Click the critical alarm count in the Alarm Dashboard.

    2. Click this alarm number.

    3. Click the date of the occurrence.

    4. Click the associated UI object.

  3. Make note of the ASP ID in the Event Context. Use this information to identify the ASP to which this association belongs by doing the following:
    1. Click SG in the side menu.

    2. Click SUA.

    3. Click SUAConfigured ASPs.

    4. Click the ASP with the name and ASP ID identified in the Event Context.

    5. Click the ASP Association identified in the alarm Event Context.

  4. Use the Remote IP Address and Port to identify the ASP Association.

  5. Reconfigure this association with more than one out stream. Valid values are 2 to 256.

  6. After completing the task in step 5, the ASP can re-establish its ASP Association.