Number | 7155 |
Severity | Critical |
SNMP Name | ptLinksetSs7LinksetInaccessible |
Description | This event indicates that an SS7 linkset is no longer accessible. Possible cause for this event is that the links in the linkset are no longer aligned. |
Application | MTP3 |
Action | See the following Recommended Action |
Recommended Action
If this alarm is raised, follow these steps.
- Log in to the Web UI as root.
- Locate the Alarm.
- Click on the critical alarm count in the Alarm Dashboard.
- Click on this alarm number.
- Click on the date of the occurrence.
- Click Associated UI Object.
- Click on the critical alarm count in the Alarm Dashboard.
- Note the Linkset State.
- If the State is Inactive, click Activate.
- If the State is Failed, then all links in the linkset are down.
- If the State is Inactive, click Activate.
Tip
See 7121 ss7L2LinkUnaligned to diagnose link alignment issues.