Parameter Name | Required | Service Affecting | Data Type | Default Value | Possible Values | Description |
---|---|---|---|---|---|---|
Description | No | No | string | none | 64 - Max Length | A description of the profile. |
FxsLineType | Yes | No | Enum | 0 | Possible values:
| Used to decide if this Loop Start FXS profile is applied to analog or digital. Not currently supported. |
Orientation | Yes | No | Enum | 1 | Possible values:
| Set the CAS signaling orientation to Network (FXS). Not currently supported. |
LoopStartType | Yes | Yes | Enum | 2 | Possible values:
| Set the Signaling Type for this Loop Start protocol. |
ForwardDisconnectDuration | Yes | No | int | 700 | Possible values:
| Used to set the time that qualifies a valid forward disconnect (battery removal) that the system will accept. The value specifies the time in milliseconds. |
FlashhookSignalDetection | Yes | No | Enum | 1 | Possible values:
| Used to set if the SBC should detect flashhook signals. Set to "true" to enable or "false" to disable. |
MaximumFlashhookDuration | Yes | No | int | 700 | Possible values:
| Used to set the maximum duration of the flashhook that will be received. Value is the time in milliseconds. Not used when FlashhookSignalDetection is set to "false". |
MinimumFlashhookDuration | Yes | No | int | 200 | Possible values:
| Used to set the minimum duration of the flashhook that will be received. The value specifies the time in milliseconds. Not used if FlashhookSignalDetection is "false". |
DisconnectToneGeneration | Yes | No | Enum | 0 | Possible values:
| Used to set whether a Disconnect Tone should be generated when the call is disconnected from the far end. Set to "true" to enable or "false" to disable. |
RevBattIncomingImmediate | Yes | No | Enum | 0 | Possible values:
| Used to set whether battery polarity should be reversed on off-hook and disconnect only (for special use, PortaOne elevator devices). Set to "true" to enable or "false" to disable. |
CadenceOnTime | Yes | No | int | 2000 | Possible values:
| Used to set the cadence on time (that the local Ring Tone is audible) for a ring generated on the analog FXS side. The value is specified in milliseconds. This parameter is valid only when Group Type is set to Analog. |
CadenceOffTime | Yes | No | int | 4000 | Possible values:
| Used to set the cadence off time (that the local Ring Tone is inaudible) for a ring generated on the analog FXS side. The value is specified in milliseconds. This parameter is valid only when Group Type is set to Analog. |
CadenceOnTime2 | Yes | No | int | 400 | Possible values:
| Used to set the second cadence on time for a double ring generated on the analog FXS side. The value is specified in milliseconds. This parameter is valid only when Group Type is set to Analog and DoubleCadence is set to "true". |
CadenceOffTime2 | Yes | No | int | 2000 | Possible values:
| Used to set the second cadence off time for a double ring generated on the analog FXS side. The value is specified in milliseconds. This parameter is valid only when Group Type is set to Analog and DoubleCadence is set to "true". |
DoubleCadence | Yes | No | Enum | 0 | Possible values:
| Indicating if Double Cadence is used to generate a double ring on the analog FXS side. Set to "true" to enable and "false" to disable. This parameter is valid only when Group Type is set to Analog. |
InterDigitTimeout | Yes | No | int | 4000 | Possible values:
| Used to set the timeout time between dialed numbers. The value specifies the timeout period in milliseconds. |
The POST can contain either only the attributes that are being updated, or the full set of attributes for the resource