Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.31.0.1

Description

This alarm indicates that an HPC call is attempted without HPC license. The call proceeds as a normal call and the SBC does not treat it as an HPC call. This alarm warns the operator to purchase an HPC license so that the HPC calls have priority treatment.

Repetition

Yes. This alarm repeats any time the SBC attempts an HPC call. There is a minimum of an hour between alarm.

Event Codes

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription

Instance Fields

  • sonusAlarmLevel
  • sonusAlarmDescription

Action

Purchase an HPC license.

Impact

The SBC does not process the attempted HPC calls with priority.

Clearing

Manual.