This section specifies the parameters and controls used for digit parameter handling for this trunk group for this H.323 trunk group.
On SBC main screen, go to Configuration > System Provisioning > Category: Trunk Provisioning > Trunk Group > H323Trunk Group > Policy > Digit Parameter Handling. The Digit Parameter Handling window is displayed.
The Digit Parameter Handling can be checked for each Address Context, for each Zone, for each H323Trunk Group created or for all the Address Contexts, Zones and H323Trunk Groups created. Use the drop-down box to select the desired Address Context, Zone and H323Trunk Group.
The Edit Digit Parameter Handling window is displayed.
Figure 1: H323 Trunk Group - Digit Parameter Handling Edit Window
The following fields are displayed:
Table 1: H323 Trunk Group - Digit Parameter Handling Parameters
|
|
---|---|
| Specifies the name of the Numbering Plan profile. The options are:
|
| Specifies the name of Digit Manipulation/Parameter Manipulation profile applied at the ingress. The options are:
|
| Specifies the name of the Digit Manipulation/Parameter Manipulation profile applied at the egress. The options are:
|
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.