DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

TypeCRITICAL

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.19.0.6

Description

This alarm indicates that the SBC was unable to register with the License Manager during the grace period.

Repetition

Repeats for each occurrence.

Event Codes

EVENT_LICENSE_MANAGER_REGISTRATION_PERIOD_EXPIRED

Instance Fields

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusLicenseManagerGracePeriod

Action

Check the previous alarms regarding registration failures and take the actions indicated.

Reconnect the SBC to the managing EMS/RAMP instance.

Impact

The SBC has been disconnected from the managing EMS/RAMP for an extended period, resulting in the SBC operating in an unsanctioned manner from a licensing perspective. Reconnect the SBC to the managing EMS/RAMP instance. Contact Ribbon Global Product Support for more information regarding the need for the SBC to remain in constant contact with the managing EMS/RAMP instance.

Clearing

automatic; sonusCpLicenseManagerRegistrationSucceeded