In this section:
This section explains how to add, activate, edit and delete troubleshooting rules in the EdgeView SCC.
Troubleshooting Rules provide an essential service assurance feature in the EdgeView that includes superior configuration, troubleshooting, remediation, and analytical capabilities. It allows you to automate and modify rules that define events and associated actions.
Perform the following steps to add a new troubleshooting rule in the EdgeView.
Choose Troubleshooting > Rules.
The Rules page appears.
Select ADD NEW RULE to add a new rule (see Rules page image). The Add New Rule page appears.
Rule Name: Enter a rule name of your choice.
Trigger Type: Click on the drop-down list (see Rule Triggers image) to choose from six different triggers that are listed below:
EdgeMarc Down: When the EdgeView loses contact with the EdgeMarc.
MOS Below Threshold: When MOS score falls below a pre-configured threshold on an individual EdgeMarc.
SIP server Unavailable: When the EdgeMarc loses contact with the SIP server.
SIP server Mode Change: When the EdgeMarc goes into/out of survivability.
SIP server Change: When, due to redundancy, the EdgeMarc switches to the next SIP server on the list or switches back to the high priority one.
WAN Link Change: When there is a WAN link status change (up/down).
Rule: Define the rule depending on the trigger type.
Actions: Choose the actions to perform based on the trigger type.
Rule Severity: Choose the desired rule severity (see Rule Severity image).
Define Scope: Click SELECT COLLECTION OR DEVICE to select the device or collection to apply the rule against.
Notify: Click ADD RECIPIENTS to add users who will receive notifications when this rule is triggered.
Leave the Active box selected to ensure that the rule remains active (see Active Check-box image).
After defining the rule, select ADD RULE to add the new rule.
A dialog box displays confirming the rule is added successfully.
Upon successful addition of new rule, you are redirected to the Rules page (see Rules page image). To activate a rule, follow the steps below:
Select the check-box under Active, corresponding to the rule you want to activate (see Activate Rule image).
A dialog box displays confirming the rule is turned on successfully.
Select CLOSE (see Rule Activated image).
To edit a rule, follow the steps below:
Click the edit icon on the right side of the Rules page.
To delete a rule, follow the steps below:
Click the delete icon on the right side of the Rules page (see Edit Rule image).
You are prompted to confirm the deletion.