Type: CRITICAL

Description

This alarm is Generated when Accounting Records are no longer being generated on the Node
Possible causes:
A change to the accounting configuration
Errors in the logging mechanism, such as file logging errors.
When the reason specified for accounting out-of-service is an event logging error, and then the SYS event logs on the Node should be examined to obtain further information about the event logging failure.

Repetition

None

Event Codes

sonusAcctOutOfServiceReason—The Reason Node is Out-of-Service. Values include:
configChange(1)
eventLoggingError(2)

Instance Fields

None

Action

None

Impact

No Call Detail Records (CDRs) are generated

Clearing

Automatic, sonusSbxCallAccountingInServiceNotification