This object allows you to configure signaling timers for the node.

To View and Edit H323 Sig Timers

On SBC main screen, go to Configuration > Profile Management > Category: Signaling Timers > H323 Sig Timers.

The H323 Sig Timers window is displayed.

Profile Management - Signaling Timers - H323 Sig Timers

 

The following fields are displayed:

H323Sig Timers Parameters

Parameter Description
EstablishSpecifies the H225 signal channel establishment timer (in seconds). The value ranges from 0 to 127 seconds and the default value is 4 seconds.
Tcp ConnectSpecifies the TCP connect timer (in seconds). The value ranges from 0 to 127 seconds and the default value is 3 seconds.
T301Specifies the T301 call timer (in seconds). The value ranges from 0 to 65535 seconds and the default value is 180 seconds.
T302Specifies the T302 call timer (in seconds). The value ranges from 0 to 127 seconds and the default value is 15 seconds.
T303Specifies the T303 call timer (in seconds). The value ranges from 0 to 127 seconds and the default value is 4 seconds.
T304Specifies the T304 call timer (in seconds). The value ranges from 0 to 127 seconds and the default value is 20 seconds.
T310Specifies the T310 call timer (in seconds). The value ranges from 0 to 127 seconds and the default value is 10 seconds.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

 