The SBC application revert from version 7.0.0R000 to the previous version is performed using the SBC EMA with the following prerequisites:
The following procedure describes the
Launch the EMA (from either the active or standby server). Refer to Logging On to EMA in Platform Mode for guidance.
Navigate to Monitoring > Dashboard > System and Software Info to verify the versions.
Navigate to Administration > System Administration screen.
Click Revert Software Version.
The Revert Software Version screen is displayed. This displays the System or Partition for the current version and the older version.
A confirmation message appears on the screen. Click Ok to proceed.
The Revert Software application simultaneously reverts both the Active (WFDSBC01a) and Standby (WFDSBC01b) server. On continuing with the revert, the upgraded server(s) will reboot and come up with an earlier release. During this process browser session will be lost and need to re-login.
The Revert Software starts and changes the boot version to earlier version in both the active and standby server. For example, in this case, it is 06.02.00R000 version. You can see the revert status in the Log section.
Once you see Rebooting message in the logs, log out from the EMA.
The revert operation takes approximately 15 to 20 minutes to complete.
Beginning with 5.0 release, the Platform Manager is integrated into the EMA and hereafter referred to as EMA Platform Mode. So once it is reverted back to 3.x/4.x release, you may only use Platform Manager tool for further upgrades.
The roles of Active and Standby server may interchange depends upon the server, which is booting first. In this case, WFDSBC01b completed the rebooting first and became active.