In this section:

The IP Policing Alarm Profiles specify parameters to determine when alarms associated with IP policing are generated and cleared.

To View IP Policing Alarm Profiles

On the SBC main screen, choose a path:

  • Configuration > Profile Management > Category: System Profiles > IP Policing Alarm Profile
  • All Profiles > System > IP Policing Alarm Profile


The IP Policing Alarm Profile window is displayed. A  portion of the window is shown below.

To Create an IP Policing Alarm Profile

To create a new IP Policing Alarm Profile, click New IP Policing Alarm Profile on the IP Policing Alarm Profile List window.

The Create New IP Policing Alarm Profile window is displayed.


IP Policing Alarm Profile Parameters:

Parameter

Length/Range

Default

Description

Name

1-23

N/A

The name of the IP Policing Alarm profile.

Index

N/A

N/A

A unique identifier.

State

N/A

Disabled

Administrative state of IP Policing alarm profile.

Bad Ethernet IP Header Set Threshold

0-2147483647

100

The threshold for the bad Ethernet IP header policer discard rate (in pkts/sec) which may set an alarm.

Bad Ethernet IP Header Clear Threshold

0-2147483647

20

The threshold for the bad Ethernet IP header policer discard rate (in pkts/sec) which may clear an alarm.

Bad Ethernet IP Header Set Duration

0-2147483647

3

The duration (in seconds) that the bad Ethernet IP header policer discard rate (in pkts/sec) must be at or above its set threshold before an alarm is set.

Bad Ethernet  IP Header Clear Duration

0-2147483647

3

The duration (in seconds) that the bad Ethernet IP header policer discard rate (in pkts/sec) must be at or below its clear threshold before an alarm is cleared.

ARP Set Threshold

0-2147483647

100

The duration (in seconds) that the bad Ethernet IP header policer discard rate (in pkts/sec) must be at or below its clear threshold before an alarm is cleared.

ARP Clear Threshold

0-2147483647

20

The threshold for the ARP policer discard rate (in pkts/sec) which may clear an alarm.

ARP Set Duration

0-65535

3

The duration (in seconds) that the ARP policer discard rate (in pkts/sec) must be at or above its set threshold before an alarm is set.

ARP Clear Duration

0-65535

3

The duration (in seconds) that the ARP policer discard rate (in pkts/sec) must be at or below its clear threshold before an alarm is cleared.

U Flow Set Threshold

0-2147483647

100

The threshold for the micro flow policer discard rate (in pkts/sec) which may set an alarm.

U Flow Clear Threshold

0-2147483647

20

The threshold for the micro flow policer discard rate (in pkts/sec) which may clear an alarm.

U Flow Set Duration

0-65535

3

The duration (in seconds) that the micro flow policer discard rate (in pkts/sec) must be at or above its set threshold before an alarm is set.

U Flow Clear Duration

0-65535

3

The duration (in seconds) that the micro flow policer discard rate (in pkts/sec) must be at or below its clear threshold before an alarm is cleared.

ACL Set Threshold

0-2147483647

100

The threshold for the access control list (ACL) policer discard rate (in pkts/sec) which may set an alarm.

ACL Clear Threshold

0-2147483647

20

The duration (in seconds) that the access control list policer discard rate (in pkts/sec) must be at or below its clear threshold before an alarm is cleared.

ACL Set Duration

0-65535

3

The duration (in seconds) that the access control list policer discard rate (in pkts/sec) must be at or above its set threshold before an alarm is set. A value of 0 sets the alarm immediately.

ACL Clear Duration

0-65535

3

The duration (in seconds) that the access control list policer discard rate (in pkts/sec) must be at or below its clear threshold before an alarm is cleared. A value of 0 clears the alarm immediately.

Aggregarte Set Threshold

0-2147483647

100

The threshold for the aggregate policer discard rate (in pkts/sec) which may set an alarm.

Aggregarte Clear Threshold

0-2147483647

20

The threshold for the aggregate policer discard rate (in pkts/sec) which may clear an alarm.

Aggregate Set Duration

0-65535

3

The duration (in seconds) that the aggregate policer discard rate (in pkts/sec) must be at or above its set threshold before an alarm is set.

Aggregate Clear Duration

0-65535

3

The duration (in seconds) that the aggregate policer discard rate (in pkts/sec) must be at or below its clear threshold before an alarm is cleared. A value of 0 clears the alarm immediately.

IP Sec Decrypt  Set Threshold

0-2147483647

100

The threshold for the IPSEC decrypt policer discard rate (in pkts/sec) which may set an alarm. 

IP Sec Decrypt Clear Threshold

0-2147483647

20

The threshold for the IPSEC decrypt policer discard rate (in pkts/sec) which may clear an alarm. 

IP Sec Decrypt  Set Duration

0-65535

3

The duration (in seconds) that the IPSec decrypt policer discard rate (in pkts/sec) must be at or above its set threshold before an alarm is set.

IP Sec Decrypt Clear Duration

0-65535

3

The duration (in seconds) that the IPSec decrypt policer discard rate (in pkts/sec) must be at or below its clear threshold before an alarm is cleared.

Media Set Threshold

0-2147483647

100

The threshold for the media policer discard rate (in pkts/sec) which may set an alarm.

Media Clear Threshold

0-2147483647

20

The threshold for the media policer discard rate (in pkts/sec) which may clear an alarm.

Media Set  Duration

0-65535

3

The duration (in seconds) that the media policer discard rate (in pkts/sec) must be at or above its set threshold before an alarm is set.

Media Clear Duration

0-65535

3

The duration (in seconds) that the media policer discard rate (in pkts/sec) must be at or below its clear threshold before an alarm is cleared.

Rogue Media Set Threshold

0-2147483647

100

The threshold for the rogue media policer discard rate (in pkts/sec) which may set an alarm.

Rogue Media Clear Threshold

0-2147483647

20

The threshold for the rogue media policer discard rate (in pkts/sec) which may clear an alarm.

Rogue Media Set Duration

0-65535

3

The duration (in seconds) that the rogue media policer discard rate (in pkts/sec) must be at or above its set threshold before an alarm is set.

Rogue Media Clear Duration

0-65535

3

The duration (in seconds) that the rogue media policer discard rate (in pkts/sec) must be at or below its clear threshold before an alarm is cleared.

Discard Rule Set Threshold

0-2147483647

20

The threshold for the discard rule discard rate (in pkts/sec) which may set an alarm.

Discard Rule Clear Threshold

0-2147483647

10

The threshold for the discard rule discard rate (in pkts/sec) which may clear an alarm.

Discard Rule Set Duration

0-65535

3

The duration (in seconds) that the discard rule discard rate (in pkts/sec) must be at or above its set threshold before an alarm is set. A value of 0 sets the alarm immediately.

Discard Rule Clear Duration

0-65535

3

The duration (in seconds) that the discard rule discard rate (in pkts/sec) must be at or below its clear threshold before an alarm is cleared. A value of 0 clears the alarm immediately.

Srtp Decrypt Set Threshold

0-2147483647

20The threshold for the SRTP decrypt policer discard rate (in pkts/sec) which may set an alarm. 
Srtp Decrypt Clear Threshold0-214748364710The threshold for the SRTP decrypt policer discard rate (in pkts/sec) which may clear an alarm. 
Srtp Decrypt Set Duration

0-65535

3

The duration (in seconds) that the SRTP decrypt policer discard rate (in pkts/sec) must be at or above its set threshold before an alarm is set. 

Srtp Decrypt Clear Duration

0-65535

3

The duration (in seconds) that the SRTP decrypt policer discard rate (in pkts/sec) must be at or below its clear threshold before an alarm is cleared. 

Make changes to the parameter values as needed and click Save to create the profile.

To Edit an IP Policing Alarm Profile

  1. To edit an IP Policing Alarm Profile, click the radio button next to the specific IP Policing Alarm Profile name. The Edit Selected IP Policing Alarm Profile window is displayed.
  2. Make the required changes and click Save.

To Copy an IP Policing Alarm Profile

  1. To copy an IP Policing Alarm Profile, click the radio button next to the specific IP Policing Alarm Profile to highlight the row.
  2. Click Copy IP Policing Alarm Profile. The Copy Selected IP Policing Alarm Profile window is displayed.
  3. Make any changes to the required fields and click Save. The new IP Policing Alarm Profile based on the copied profile is added at the bottom of the list.

To Delete an IP Policing Alarm Profile

  1. To delete any of the created IP Policing Alarm Profiles, click the radio button next to the specific IP Policing Alarm Profile.
  2. Click the X at the right end of the highlighted row. 
  3. Click Yes to confirm the deletion when prompted.


  • No labels