In this section:


The Action pane is available for new Sip Adaptor Profile or Edit mode of an existing Sip Adaptor Profile.

  1. On the SBC main screen go to Configuration > System Provisioning > Trunk Provisioning > SIP Adaptor (SMM) Profile.
    The SIP Adaptor (SMM) Profile window is displayed.
    Figure 1: SIP Adaptor (SMM) Profile


  2. Select the SIP Adaptor Profile you wish to edit or create a new SIP Adaptor Profile. The Action pane is displayed at the bottom.
    Figure 2: Action


To Store Header Values to SMM CDR

Perform the following procedure in the Action pane to store Header value to CDR.

  1. From the Type drop-down list, select Header.
  2. From the sub drop-down list, select write a header to the CDR.

  3. In the named field, enter a header name.

  4. From the store the drop-down list, select header value.
  5. From the to drop-down list, select a CDR field SMM.

  6. Click Add Action.

    The action is created.

To Store Token Values to SMM CDR

Perform the following procedure in the Action pane to store token value to CDR.

  1. From the Type drop-down list, select Token.
  2. From the sub drop-down list, select write a token to the CDR.

  3. From the of the type drop-down list, select a type.
  4. From the to drop-down list, select a CDR field SMM.

  5. Click Add Action.
    The action is created.

To Store Parameter Value to CDR

Perform the following procedure in the Action pane to store user info parameter value to CDR.

  1. From the Type drop-down list, select Parameter.
  2. From the sub drop-down list, select write a parameter to the CDR.

  3. From the of the typedrop-down list, select a type. Options are:
    1. user info
    2. URI
    3. generic
  4. In the named field, enter a header name.
  5. From the to drop-down list, select a CDR field SMM.

  6. Click Add Action.
    The action is created.

  • No labels