This section specifies the R-Factor signaling quality measurement.

To View and Edit Qoe - Rfactor

On SBC main screen, go to Configuration > System Provisioning > Category: Trunk Provisioning > Trunk Group > H323Trunk Group > H323 Trunk Advanced > Qoe > Rfactor. The Rfactor window is displayed.

The Qoe - Rfactor can be checked for each Address Context, for each Zone, for each H323Trunk Group created or for all the Address Contexts, Zones and H323Trunk Groups created. Use the drop-down box to select the desired Address Context, Zone and H323Trunk Group.

The Edit Rfactor window is displayed.

H323 Trunk Advanced - Qoe - Rfactor Edit Window

 

The following fields are displayed:

H323 Trunk Advanced - Qoe - Rfactor Parameters


Parameter


Description

Critical Qos RFactor LimitSpecifies the critical R-Factor limit, below which the call admission should be stopped. The value range from 0 - 100 and the default value is 50.
Major Qos RFactor LimitSpecifies the major R-Factor limit, below which the call admission should be reduced. The value range from 0 - 100 and the default value is 70.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

 