Type: MAJOR
Object iD | 1.3.6.1.4.1.2879.2.8.1.2.1.12.0.5 |
Description | This alarm indicates processor Media Error rate has exceeded the configurable "setThreshold" for this system. |
Repetition | None |
Event Codes | sonusMediaErrType |
Instance Fields | None |
Action | If the problem persists, examine the IP Sec Decrypt Offenders policer list for potential issues. Refer to, Policers - IP Sec Decrypt Offenders List for more information. |
Impact | Communication integrity of the media stream maybe compromised or becomes unreliable. |
Clearing | Automatic; sonusSystemSecurityMediaErrClearNotification |