Type: MINOR 

Object ID1.3.6.1.4.1.2879.2.10.1.1.1.0.16

Description

This alarm indicates that an Address of Record (AOR) registering from multiple contact addresses is reusing a signaling port towards the registrar. This alarm is generated once per zone.

Repetition

None

Event Codes

sonusSipAorSigZoneId

Instance Fields

None

Action

Ensure enough signaling ports are allocated in the zone.

Impact

Calls are not routed towards the AOR registered prior to this registration unless the registrar supports reg-info parameter.

Clearing

Manual

  • No labels