The following table lists the SBC feature license keys that apply in the network-wide domain license (NWDL) environment. NWDL license keys contain a suffix of "-D" to distinguish them from similar license keys used in node-locked licensing.
Feature ID | Usage | Type |
---|---|---|
DSP-AMRNB-D | RTU media interworking using AMRNB. Use license to enable AMR-NB audio transcoding. (DSP modules required) Note: Both DSP-AMRNB-D and VDSP-RTU-D licenses are required to transcode AMR-NB for SBC SWe. | Count |
DSP-AMRWB-D | RTU media interworking using AMRWB. Use license to enable AMR-WB audio transcoding. (DSP modules required) | Count |
DSP-EVRC-D | RTU media interworking using EVRC. Use license to enable EVRC audio transcoding. (DSP modules required) Note: This license is not applicable to SBC SWe because EVRC is not supported. | Count |
DSP-EVS-D | RTU media interworking using EVS. Use license to enable EVS transcoding. (DSP modules required) | Count |
DSP-G722-D ($0 charge) | RTU media interworking using G.722. Use license to enable G.722 audio transcoding. (DSP modules required) Note: Ribbon does not charge for the G.722 codec; however, the SBC 5xx0/7000 series code still checks for this license. Because of this, a $0 charge DSP-G722-D license must be generated and installed on SBC 5xx/7000 series in order to use G.722 features. | On/Off |
DSP-SILK-D | RTU media interworking using SILK. Use license to enable SILK transcoding. (DSP modules required) | Count |
ENCRYPT-D | Encryption function for signaling using TLS, IPsec. | Count |
LB-INSTANCE | Enables the operation of the SLB. | On/Off |
MEDIA-PROBE | Enables the Media Probe functionality to monitor voice quality on the SBC. | On/Off |
SBC-LB | Enables the SLB feature on the SBC. If the value is non-zero, it allows a specified number of SLB sessions on the system. If zero, no SLB sessions are allowed. | Count |
SBC-P-DCS-LAES | Enables the Lawfully Authorized Electronic Surveillance(LAES) functionality. | On/Off |
SBC-RTU-D | Controls the right-to-use (RTU) for SIP and H.323 sessions. The following type of media sessions are enabled:
| Count |
SBC-SOSBC-RTU | Controls the right-to-use (RTU) for SIP sessions when the SBC is configured for signaling-only mode. Note: When the SBC is configured for signaling-only mode, the total SIP sessions allowed are the total of the SBC-SOSBC-RTU and SBC-RTU-D licenses. | Count |
SBC-SIP323-D | SIP/H.323 Interworking function. | On/Off |
SBC-POL-RTU-D | SBC Advanced ERE RTU per session license. Note: If both "SBC-POL-E911-D" and "SBC-POL-ENUM-D" licenses are installed, the "SBC-POL-RTU-D" license is not required. | Count |
SBC-SIP-I-D | SIP-I interworking function. | On/Off |
SRTP-D | Encryption function for media using secure RTP. | Count |
SBC-VIDEO-D | Video interworking support, including Content Sharing (BFCP), Far-End Camera Control (FECC) and H.239 for H.323 | Count |
SBC-MRF-RTU-D | Required to enable transcoding using an external Media Resource Function (MRF) device. The SBC-MRF-RTU-D license is not a substitute for the SBC-RTU-D session license. Both the licenses are required to allow a session towards the MRF. The SBC-MRF-RTU-D license is only applicable to the S-SBC when deploying the distributed-SBC architecture. | Count |
SBC-CAPACITY-D | Enables use of SBC features up to the capacity of the node. Actual license usage is reported to Ribbon using EMS statistics. | On/Off |
SBC-1X10GMP-D | SBC 5400 RTU license to enable media port(s) operating at 10 Gbps. This will activate two 10 Gbps packet ports. | On/Off |
SBC-4X1GMP-D | SBC 5400 RTU license to enable all four media ports. each operating at 1 Gbps. Note: If the SBC 5400 is configured for two 1 Gbps media ports (default configuration), no license is required). | On/Off |
SBC-LI-D | Enables support for Lawful Intercept service using ERE. | On/Off |
SBC-POL-ENUM-D | SBC ERE support for accessing ENUM databases. | On/Off |
SBC-POL-E911-D | RTU license for E911 service. | On/Off |
SBC-SIPREC-D | SIPREC session recording support. | Count |
SBC-NICEREC-D | Session recording using the NICE proprietary recording system. | Count |
SWE-INSTANCE-D | Required to run SBC software in an SBC SWe environment. | On/Off |
VDSP-RTU-D | Enables transcoding feature in SBC SWe. If value is non-zero, it allows specified number of transcoded calls on the system. If zero, no transcoded calls are allowed. VDSP-RTU-D count should be always less than or equal to SBC-RTU-D count. If not, no transcoded calls are allowed. Note: Any additional emergency oversubscription is not supported for transcoded emergency calls on SBC SWe. | Count |
WEBSOCKET | Enables support for SIP signaling from WebRTC endpoints over a WebSocket transport. If value is non-zero, it allows the specified number of WebSocket calls on the system. If zero, no WebSocket calls are allowed. | Count |